Hire mold consultants Phillip Fry and Divine Fry to find air conditioning mold, workplace mold, and mold hidden inside the walls, ceilings, floors, crawl space, attic, basement, and HVAC equipment and system of your house, condominium, office, workplace, or other building anywhere in Chandler, Flagstaff, Mesa, Peoria, Phoenix, Scottsdale, Tempe, Tucson, and anywhere else in Arizona.  Lead Test Kits Mold Training  Mold Inspector Directory  Industrial Hygienist Training  Industrial Hygienist Directory  Mold Inspection Questions & Answers


Ozone: Science & Engineering
-
revised Feb 09
The Practical Application of Ozone Gas as an Anti-fungal (Anti-mold) Agent
 
Sharma, Manju; Hudson, James Viroforce Systems Inc. Laboratory, Vancouver, Canada Key words
: Ozone; fungi; mold; anti-fungal; healthcare; environmental fungi; Stachybotrys chartarium; Trichoderma viride; Correspondence: Dr. JB. Hudson (and Dr. Manju Sharma), Department of Pathology & Laboratory Medicine, University of British Columbia, C-360 Heather Pavilion, 2733 Heather Street, Vancouver V5Z 3J5, Canada. Tel.no.1- 604-875-4351 Fax no.1- 604-875-4351

E-mail: jbhudson@interchange.ubc.ca Running Title: Ozone Gas as an Antifungal Agent Abstract We evaluated the ability of a portable ozone generating machine (Viroforce 1000) to inactivate 13 different species of environmental fungi. Samples, prepared as wet or dried films, were subjected to one or two cycles of treatment (35 ppm ozone for 20 minutes, with a short burst of >90% relative humidity), and measured for residual viability. Treatments could inactivate 3 log10 cfu (colony forming units) of most of the fungi, both in the laboratory and in simulated field conditions, on various surfaces. We conclude that the ozone generator would be a valuable decontamination tool for mold removal in buildings.

Introduction

The presence of mold in buildings is associated with adverse health outcomes. Many different microbes, including a variety of fungal and bacterial species, thrive in the conditions offered by moist building materials, which contain both the nutrients and the moisture needed for microbial growth. This has given rise to the designation of “sick building syndrome” (SBS) to people afflicted directly or indirectly by the presence of fungal or bacterial products on surfaces and in the air. Similar situations have been documented in health care facilities, especially intensive care units, where there may be patients who are particularly vulnerable to microbial contaminants (Hope and Simon, 2007; Gniadek and Macura, 2007; Huttunen et al, 2008; Gottschalk et al, 2008). In addition to the risk of fungal infection in immune compromised individuals, microbial products can include mycotoxins, endotoxins, and various microbial volatile organic compounds (mVOC’s). These products may be cytotoxic, allergenic, or inducers of pro-inflammatory mediators (Hope and Simon, 2007; Huttunen et al, 2008). 2

A variety of mold cleanup methods are available for remediating damage to building materials and furnishings caused by mold growth, with some success (Kleinheinz et al, 2006). These include mechanical methods, which have inherent drawbacks, including cost, labor, and inhalation of spores. For example wet vacuums may spread spores if sufficient liquid is not present. Porous materials that are wet and have mold growing on them may have to be discarded. Since molds can infiltrate porous substances and grow on or fill in empty spaces or crevices, the mold can be difficult or impossible to remove completely. Sodium hypochlorite aerosols have been found to be effective, but are not generally acceptable (Martyny et al, 2005). Building remediation has been estimated to comprise a multibillion dollar industry in the USA alone (Kleinheinz et al, 2006); consequently there is a financial incentive, as well as health concerns, to come up with an acceptable, efficient, anti-mold treatment. Ozone has been shown to be an effective anti-bacterial treatment, in aqueous solution and in gaseous form, in several types of application, such as laundries and food protection (Bialka and Demirci, 2007; Naitou and Takahara, 2008; Selma et al, 2008; Akbas et al, 2008). Ozone gas has several advantages over alternative liquid treatments; it is easy and cheap to produce from air or oxygen, it diffuses quickly into all parts of a room, including cracks and crevices, and, although toxic at high doses, dissociates naturally to oxygen. Dosages can be controlled remotely from outside a treated sealed room. It is also a strong oxidizing agent which has the potential of not only inactivating microbes on various surfaces (Sharma and Hudson, 2008), but is also an efficient de-odorizing agent, and might be capable of inactivating the microbial products referred to above. Korzun et al (2008) recently evaluated the efficacy of ozone gas against several environmentally important fungi, and obtained promising results, although their ozone dosage was below what we have described as effective anti-viral and anti-bacterial concentrations (Hudson et al, 2007; Sharma and Hudson, 2008). This report describes the use of a proprietary portable ozone generator as a practical anti-fungal device.

Materials and Methods

Equipment. The laboratory test chamber was a molded polycarbonate box with a transparent plastic front window that could be lifted to allow access to samples. Within the test chamber was a small ozone generator (Treated Air Systems, Vancouver) fitted with a control dial that could be pre-set to known ozone doses in ppm, an ozone sampler tube connected to the exterior ozone measuring system (see below) and the probe of a hygrometer for measuring relative humidity and temperature. Humidity was applied manually as a mist of deionized sterile water.

The test room for field trials was an office, volume 34 m3, containing normal office furniture, which was located adjacent to the laboratory. In this test system we used a model 1000 Viroforce ozone generator, which is a portable module containing 3

multiple corona discharge units, a circulating fan, and an efficient catalytic converter (scrubber) to reconvert ozone to oxygen at the termination of the ozone exposure period (Fig 1). In addition a portable commercial humidifier (Humidifirst Inc, Florida) was used to provide a burst of water vapor when required. All the components were controlled remotely from outside the test room. In both test situations ozone concentration was monitored continuously by means of an Advanced Pollution Instrumentation Inc. model 450 system (from Teledyne, San Diego), which measured samples of ozonated air passed through a UV spectrometer. The input teflon sampling tube could be taped in an appropriate location for the duration of the experiment. Relative humidity and temperature were recorded by a portable hygrometer (VWR Scientific, Ontario). The probe was taped in a convenient location inside the test room. In preliminary trials we used 2-3 manual ozone sensors (Ecozone, USA) located at random sites within the room to confirm homogeneous distribution of the ozone gas. The variation in recorded levels between sensors and the monitor probe was less than ± 10%. Materials. The lids of sterile polystyrene tissue culture trays were used as plastic surfaces. Samples of fabrics and cotton (typical of those used in hospital and hotel rooms) were cut into small pieces, cleaned in detergent, washed, dried, and sterilized by autoclaving. Cotton tips and other materials were heated for 2 min in a microwave oven. Fetal bovine serum and PBS (phosphate buffered saline) were obtained from Invitrogen Ontario. Sterile plastic 24 well plates and other supplies were BD-Falcon brand obtained from VWR Scientific (Ontario). Sabouraud-dextrose plates were obtained from PML Microbiologicals, Willsonville, Oregon. Fungal strains: The following fungal strains were collected from various derelict buildings in B.C. and speciated by Dr. Eduardo Jovel, University of British Columbia, who kindly supplied them to us as colonies grown on agar plates: Alternaria sp. Aspergillus species (flavus, niger, fumigatus), Aureobasidium sp, Botrytis sp. Cladosporium sp. Geotrichum sp. Mucor sp. Penicillium brevicompactum, Stachybotris chartarium, Trichoderma viride, Ulocladium sp. We also used ATCC strains of Candida albicans and A. flavus. C. albicans was used both as yeast cells and hyphal form. All organisms were propagated and maintained in our laboratory on standard Sabouraud-dextrose agar plates (PML Microbiologicals, Oregon). C. albicans colonies were obtained in the same way, and mixed populations of yeast cells and hyphae (approximately 1:1) were obtained by growing the cells in Dulbecco MEM cell culture medium supplemented by 10 % fetal bovine serum. Cells and hyphae were harvested by centrifugation and resuspended in PBS for the tests. 4

Test Procedure: Inocula of filamentous fungal cultures were prepared by excision of 5mm3 blocks of agar containing actively growing mycelium and spores, and transferred to 5 mL of PBS (phosphate –buffered saline). The material was homogenized thoroughly on a vortex mixer. No attempt was made to separate mycelia from spores; thus each preparation comprised a mixture of both forms, and was assumed to be representative of growing cultures in the field. In some experiments, sterile fetal bovine serum was incorporated into the PBS to mimic an organic load (to demonstrate if organic load interferes with the fungicidal activity of ozone). The starting concentration of each preparation (cfu/mL) differed because of different growth rates and densities of the organisms within the agar blocks. Quantitative tests were carried out as follows: Each sample, consisting of 100 L drop of suspension, was applied, in duplicate, to the sterile surface of a plastic tray lid in a biosafety hood and allowed to dry (approximately 45 min). The dry samples were covered and placed at various locations within the test chamber or within the test room, and in the latter case the ozone generator and rapid humidifying device (RHD) were placed in a central location. These units were operated remotely from outside the room. All vents and windows in the test room were sealed. At the commencement of the test, the samples were uncovered, the door closed and sealed with tape, and the generator switched on by a programmable remote control. The ozone level reached 35±5 ppm within several minutes, and was maintained at this level for the balance of the 20 minutes. The RHD was then activated to produce a burst of water vapor for 5 min. Both generator and RHD were then switched off for another 5 min to allow “incubation” in the humid atmosphere (the relative humidity usually reached 99%). The catalytic converter was then turned on to remove all ozone gas. Ozone levels decreased to less than 1 ppm within 15 min. at which point the door was opened and the test samples were retrieved. All tests were conducted at ambient temperature, 19-21oC. In the laboratory tests, following the 20 min ozone exposure in the polycarbonate test chamber, the window was lifted briefly to allow the delivery of a mist of sterile pure water from a spray bottle. This resulted in a rapid increase in relative humidity to 90-99 %. All samples were reconstituted in PBS (phosphate buffered saline), and serial 10-fold dilutions were made in PBS. Recovery of samples from the non-plastic materials required additional vortexing and squeezing of the materials. However the controls for these samples were processed identically. Aliquots of 2.5L were spotted and spread out with plastic inoculating loops onto Sabouraud-dextrose plates. Control untreated samples were kept in the biosafety cabinet during the entire operation. Agar plates were incubated at 35°C for a minimum of 48h, after which fungal colonies were counted. 5

 

 


In some experiments, as indicated, the wet fungal inocula were used without drying, and in some experiments the tests with wet and dry inocula were carried out in ambient relative humidity, 40-45% RH.
Results: Laboratory Tests: All 13 fungi, including cells and hyphae of Candida albicans, were initially evaluated for susceptibility to ozone gas in the laboratory test system. Replicate 100 μL samples of the fungal suspensions in PBS were dried onto sterile plastic trays in a bio-safety cabinet, and exposed to the standard ozone dosage (35 ppm for 20 min). Preliminary tests had shown that lower concentrations of ozone were less effective. The results are summarized in Table 1. Because of the losses in cfu on drying, and the dilution factors involved in the assay procedures, we were not always able to determine the exact end points of inactivation. Nevertheless in all fungal species, greater than 3 log10 decreases were consistently obtained, provided the RH was greater than 90%. Not all species were tested at ambient RH. For C.albicans and Trichoderma viride, the corresponding values were  4.0 log10. These results also indicate that wet films of all the fungi were equally susceptible. In some experiments, up to 50% by volume of fetal bovine serum was included in the samples prior to drying. This did not affect the outcome however (data not shown). Candida albicans and Trichoderma viride were also tested on several other surfaces, filter paper, cotton, cardboard, and fabric, and were found to be equally susceptible to the ozone treatment, as indicated in Table 2. Field Tests: These were conducted in an office adjoining the laboratory. This room had a volume of 34 cu meters, and contained standard office furniture and a large window. Initially we used C. albicans to evaluate the efficacy of the prototype ozone generator and the rapid humidifier. During the standard program the ozone level rose to a maximum of 35±5 ppm within a few minutes and was maintained at this level until the 20 min point, when the humidifier was automatically switched on. The relative humidity increased rapidly from the ambient level (40-45% RH) to greater than 90% (usually 99%) within 5 min. After a further 5 min incubation at this level, the generator and humidifier were turned off and the catalytic converter activated. The ozone concentration decreased to < 1 ppm after 15 min, at which point the samples were retrieved and taken to the laboratory for processing. A single exposure of C. albicans to this treatment program consistently inactivated more than 3 log 10 cfu (Fig 2), and in most tests eradication was achieved.

The other species of fungi were tested, in groups, with the same protocol. Most of them appeared to be more resistant than C. albicans, in that a single cycle of treatment was usually insufficient to kill all the test organisms. Nevertheless a second cycle of 6

treatment, applied shortly after the first one, was much more effective, as can be seen from the results shown in Fig.2. In all cases there were fewer residual cfu following the second exposure. Consequently in subsequent tests two consecutive standard treatments were used, although the maximum ozone level attained during the second cycle was significantly lower (approximately 20 ppm) due to residual humidity from the first cycle (ozone generation efficiency was reduced somewhat in the presence of high RH). Similar results were obtained for wet films of the species indicated in Fig.2. The remaining fungal species were then tested with the two cycle program, and all were found to be susceptible, although there did appear to be some variation in relative sensitivity among the species; but this possibility was not examined systematically. The variation in maximum log10 inactivation for some species was a reflection of their different starting concentrations. Stachybotris and Botrytis were especially difficult to obtain in high cfu/mL. In additional tests, replicate samples of Trichoderma viride were dried onto plastic trays, as usual, and also on to samples of fabric, cotton, filter paper and cardboard. These were placed at various locations within the room to mimic possible contamination sites in buildings. All samples apparently showed similar sensitivity to ozone, regardless of their location or the surface on which they were dried. However, after several days of incubation of the assay plates, a few colonies appeared, in the samples reconstituted from non-plastic surfaces, and subsequently grew into the familiar mats, indicative of incomplete inactivation. Discussion Many studies have shown that exposure to indoor air microbes from moisture-damaged buildings can cause adverse health problems including irritation, respiratory infections, an increased risk of asthma development and various other symptoms and diseases as a result of mycotoxins and VOC’s (Lai, 2006; Hope and Simon, 2007; Gniadek and Macura, 2007; Huttunen et al, 2008; Gottschalk et al, 2008). In addition certain species have been associated with opportunistic life-threatening infections in immune-compromised patients (Marr et al. 2002).

Ozone decontamination has potential advantages. It can effectively penetrate every part of a room, including sites that might prove difficult to gain access to with conventional liquids and manual cleaning procedures. It can be switched on and off from the outside after the room has been made airtight. Ozone is cheap to generate and although toxic, rapidly dissociates to oxygen with a half-life of about 20 min. The use of a catalytic converter speeds up the removal considerably. Ozone gas has been advocated as a safe disinfecting agent in the food and agriculture industries (Serra et al. 2003; Bialka and Demirci, 2007; Naitou and Takahara, 2008; Akbas and Ozdemir, 2008; Selma et al, 2008), although usually at lower concentrations than those used in the present study. Nevertheless, in view of the speed and efficiency of the catalytic 7

conversion, resulting in a return to ambient levels within 15-20 minutes, and an overall treatment cycle of less than one hour, we believe that the Viroforce system is safe and practical. This study has demonstrated that our prototype ozone generator produced a fungicidal concentration of ozone (of the order of 35 ppm). The potent biocidal activity of the ozone generator after 20 min exposure time and >90% RH was demonstrated across a range of fungi including spore producing mold. Inactivation of Trichoderma samples dried onto soft surfaces, such as fabric, cotton, and filter paper, was comparable to that observed for samples on plastic, thus confirming that ozone gas can be fungicidal to samples on curtains, linen, furniture and walls in the buildings or health care facilities. This is of particular concern since some authors have suggested that gaseous ozone might be less effective against surface bound organisms (Serra et al. 2003). However this was clearly not a limitation in our studies, possibly a reflection of the higher ozone levels used by us. Korzun et al (2008) raised several issues relevant to the use of ozone gas to remove mold contamination. In their study they achieved a significant reduction in fungal cfu, but not eradication, as a consequence of exposure to ozone concentrations up to 12 ppm. We found that it was necessary to use considerably higher levels, and expose to two cycles of treatment, in order to achieve a 3 log10 reduction in most of the fungi tested, with the exception of the more sensitive C. albicans, which was readily reduced by more than 4 log10 cfu by only one cycle. We overcame the toxic potential of high ozone concentration by operating the generator and catalytic converter remotely from outside the sealed room. In the case of larger rooms more than one machine could be used in parallel. Korzun et al (2008) tested fungal conidia on the surface of agar plates. We found that several different hard and soft surfaces could be used, and the addition of serum to the samples, to mimic an organic load, did not affect the results. They were also concerned about the size limitations of their ozone generation system. However our generators can be scaled up or down to suit the demand. Their other concern was the possible limitation of testing laboratory passaged strains which might not behave the same as wild strains. Most of our fungi were isolated from derelict buildings, and received minimal passaging in the laboratory. While the use of liquid disinfectant for general decontamination requires a great deal of labor and is unsuitable for curtains, walls and ceilings, decontamination with gas is easier. Ozone treatment can also remove unpleasant odors, including those caused by mold. It is also feasible to give repeated exposures to achieve complete eradication of mold.

The mechanisms of action of ozone against fungi and other microbes are not understood; however its broad oxidizing activity against many macromolecules (Cataldo 2006) suggest that microbial membranes, proteins and nucleic acids could all be vulnerable. Nevertheless the requirement of high humidity for optimal efficacy 8

indicates that hydroxyl ions and possibly additional water-derived radicals could be involved, as suggested for the aqueous environments (Lin and Wu 2006). References Akbas, MY. Ozdemir,M. Application of gaseous ozone to control populations of Escherichia coli, Bacillus cereus, and Bacillus cereus spores in dried figs. Food microbiology 25: 386-391 (2008) Bialka, KL. Demirci, A. Decontamination of Escherichia coli O157:H7 and Salmonella enterica on Blueberries Using Ozone and Pulsed UV-Light J. Food Science 72: M391-M396 (2007) Cataldo F. Ozone Degradation of Biological macromolecules: Proteins, Hemoglobin, RNA, and DNA. Ozone: Science and Engineering 28: 317-328. (2006) Gniadek, A. Macura, AB. Intensive care unit environment contamination with fungi Adv. Med. Sci. 52: 283-287 (2007) Gottschalk, C. Bauer, J. Meyer, K. Detection of Satratoxin G and H in Indoor Air from a Water-Damaged Building. Mycopathologia 166: 103-107 (2008) Hope, AP. Simon, RA. Excess dampness and mold growth in homes: An evidence-based review of the aeroirritant effect and its potential causes. Allergy Asthma Proc. 28: 262-270 (2007) Hudson, JB. Sharma, M. and Petric, M. Inactivation of Norovirus by ozone gas in conditions relevant to healthcare. J Hosp Inf 66 ,40-45. (2007) Huttunen, K. Rintala, H. Hirvonen, M-R, Vepsalainen, A. Hyvarinen, A. Meklin, T. Toivola, M. Nevalainen, A. Indoor air particles and bioaerosols before and after renovation of moisture-damaged buildings: the effect on biological activity and microbial flora. Environ. Res. 107: 291-298 (2008) Kleinheinz,GT. Langolf, BM. Englebert E. Characterization of airborne fungal levels after mold remediation Microbiol. Res. 161: 367-376 (2006) Korzun,W. Hall, J. Sauer,R. The Effect of Ozone on Common Environmental Fungi. Clin.Lab. Sci. 21: 107-111 (2008)

Lai, KM. Hazard identification, dose-response and environmental characteristic of stachybotryotoxins and other health-related products from Stachybotrys. Environ Technol 27(3),329-35. (2006) 9

Lin Y-C. Wu S-C. Effects of ozone exposure on inactivation of intra- and extracellular enterovirus 71. Antiviral Res. 70: 147-153. (2006) Marr, KA.,Carter, RA., Crippa, F., Wald, A. and Corey, L. Epidemiology and outcome of mould infections in hematopoietic stem cell transplant recipients. Clin Infect Dis 34, 909-917. (2002) Martyny, JW. Harbeck,RJ. Pacheko, K. Barker,EA. Sills, M. Silveira, L. Arbuckle, S. Newman, L. Aerosolized sodium hypochlorite inhibits viability and allergenicity of mold on building materials. J. Allergy Clin Immunol. 116: 630-635 (2005) Naitou, S. Takahara, H. Recent developments in food and agricultural uses of ozone as an antimicrobial agent-food packaging film sterilizing machine using ozone. Ozone:science and engineering 30: 81-87 (2008) Selma, MV. Allende, A. Lopez-Galvez, F. Conesa, MA. Gil,MI. Disinfection potential of ozone, ultraviolet-C, and their combination in wash water for the fresh-cut vegetable industry. Food Microbiology 25: 809-814 (2008) Serra, R. Abrunhosa, L. Kozakiewcz, Z Venancio, A. Lima,N. Use of ozone to reduce molds in a cheese ripening room. J.Food protection 66: 2355-2358 (2003) Sharma, M. Hudson, JB. Ozone Gas is an Effective and Practical Antibacterial Agent Am J Infect Control 36: 559-563 (2008) Stark, H., Roponen, M., Purokivi, M., Randell, J., Tukiainen, H. and Hirvonen, MR. Aspergillus fumigatus challenge increases cytokine levels in nasal lavage fluid. Inhal Toxicol 18(13), 1033-9. (2006) Stratus, DC. and Wilson, SC. Respirable trichothecene mycotoxins can be demonstrated in the air of Stachybotrys chartarum-contaminated buildings. J Allergy Clin Immunol 117(2), 326-33. (2006) 10

TABLE 1. SUSCEPTIBILITY OF FUNGI TO OZONE GAS Species Log10 Reduction in CFU (colony forming units) Wet sample High RH (> 90%)

Dry sample High RH

Dry/wet sample Low RH (45%)

Aspergillus species (flavus,niger,fumigatus) Aureobasidium species Botrytis species Candida albicans (cells and hyphae) Cladosporium species Geotrichum species Mucor species Penicillium brevicompactum Stachybotris chartarium Trichoderma viride Ulocladium species

 

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

≥ 4.0

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

≥ 4.0 >3.0

 

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

≥ 4.0

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

Ø 3.0

 

≥ 4.0

Ø 3.0

 

~ 1.5 nt nt 1.5 -2.0 ~ 1.0 nt ~ 1.0 nt ~ 1.0 ~ 1.5 ~ 1.0

           

[Home] [Up] [Ozone Instruction Manual] [Ozone Generator Inside Pictures] [Ozone Treatment Q & A] [Ozone AntiFungal Study] [Ozone Kills All Mold Types] [Ozone Kills Bacteria] [Airborne Ozone Kills Bacteria] [EPA Ozone Study] [Killing Mold on Grapes] [Industrial Ozone Gas Uses] [Bedbug Insecticides Sicken People] [Ozone Use Concerns]

Hire mold consultants Phillip Fry and Divine Fry to find air conditioning mold, workplace mold, and mold hidden inside the walls, ceilings, floors, crawl space, attic, basement, and HVAC equipment and system of your house, condominium, office, workplace, or other building anywhere in Chandler, Flagstaff, Mesa, Peoria, Phoenix, Scottsdale, Tempe, Tucson, and anywhere else in Arizona.  Lead Test Kits
Mold Training  Mold Inspector Directory  Industrial Hygienist Training  Industrial Hygienist Directory  Mold Inspection Questions & Answers


 

Ozone Blasting To Kill Mold & Germs   ►Ozone Videos   ►EnviroFry™ Ozone Generator Instruction Manual  ►Ozone Q & A  
 ►
Ozone Treatment Advice Blog
Ozone Kills Mold  Ozone Removes Odors Car Mold Remediation  ►Mold Test Kits   ►Mold Inspection  ►Air Conditioning Mold  ►Allergy Dust Mites   ►Mold Removal Tips   Mold Remediation Tips  ►Workplace Mold  ►Mold Inspector Directory  ►Mold InspectionMold Training  ►Industrial Hygienist Training  ►Industrial Hygienist DirectoryMold Consultant  ►Tim-Bor  ►Lead Test Kit Mold Health   
►Mold Removal
Personal Protection Gear  ►Allergy, Asthma, & Sinusitis Mold  ►Mold Prevention  ►Mold Attorney Indoor PollutionHome Repair 
Home Remodel  ►Mold Expert  ►PollutionbustersBusiness Mold  ►Company Mold Mold Pictures  ►Mold Test Dallas Texas  ►Mold Inspection Dallas Texas  ►Houston Toxic Mold Testing  ►House Mold Testing Texas
Mold Fogging Machine  ►San Diego Mold Removal  ►Los Angeles Mold Removal  ►Mold Marines  Building Maintenance Training DIY Mold Removal  Do It Yourself Mold Removal  FREE Mold Advice Hotline   Air Conditioning Mold 
Ozone Generator 
DIY Mold
Mold Victim Rights Mold Law Mold Victim  Mold Lawsuit FREE Mold Advice Hotline